Man Linux: Main Page and Category List

NAME

       aegis integrate begin undo - reverse the aeib command

SYNOPSIS

       aegis -Integrate_Begin_Undo [ option...  ]
       aegis -Integrate_Begin_Undo -List [ option...  ]
       aegis -Integrate_Begin_Undo -Help

DESCRIPTION

       The aegis -Integrate_Begin_Undo command is used to reverse the actions
       of the aegis -Integrate_Begin command.

       Successful execution of this command will move the change from the
       being integrated state to the awaiting integration state.  The
       integration directory will be deleted.  The change will cease to be
       assigned to the current user.  boxwid = 1 down S4: box "awaiting"
       "integration" arrow " integrate" ljust " begin" ljust S5: box "being"
       "integrated" T4: spline -> from S5.w then left 0.5 then up 1 then to
       S4.w " integrate" ljust " begin" ljust " undo" ljust at T4.c - (0.5,0)

       In the unlikely event that an integrator has wandered away and left an
       integration incomplete (say, went on holidays and won’t be back for two
       weeks), project administrators are also able to use this command.

   Notification
       On successful completion of this command, the integration_begin_undo_
       command field of the project config file is run, if set.  See
       aepconf(5) for more information.

OPTIONS

       The following options are understood:

       -Change number
               This option may be used to specify a particular change within a
               project.  See aegis(1) for a complete description of this
               option.

       -Help
               This option may be used to obtain more information about how to
               use the aegis program.

       -Keep
               This option may be used to retain files and/or directories
               usually deleted or replaced by the command.  Defaults to the
               user’s delete_file_preference if not specified, see aeuconf(5)
               for more information.

       -No_Keep
               This option may be used to ensure that the files and/or
               directories are deleted or replaced by the command.  Defaults
               to the user’s delete_file_preference if not specified, see
               aeuconf(5) for more information.

       -List
               This option may be used to obtain a list of suitable subjects
               for this command.  The list may be more general than expected.

       -Project name
               This option may be used to select the project of interest.
               When no -Project option is specified, the AEGIS_PROJECT
               environment variable is consulted.  If that does not exist, the
               user’s $HOME/.aegisrc file is examined for a default project
               field (see aeuconf(5) for more information).  If that does not
               exist, when the user is only working on changes within a single
               project, the project name defaults to that project.  Otherwise,
               it is an error.

       -REAson text
               This option may be used to attach a comment to the change
               history generated by this command.  You will need to use quotes
               to insulate the spaces from the shell.

       -TERse
               This option may be used to cause listings to produce the bare
               minimum of information.  It is usually useful for shell
               scripts.

       -Verbose
               This option may be used to cause aegis to produce more output.
               By default aegis only produces output on errors.  When used
               with the -List option this option causes column headings to be
               added.

       -Wait   This option may be used to require Aegis commands to wait for
               access locks, if they cannot be obtained immediately.  Defaults
               to the user’s lock_wait_preference if not specified, see
               aeuconf(5) for more information.

       -No_Wait
               This option may be used to require Aegis commands to emit a
               fatal error if access locks cannot be obtained immediately.
               Defaults to the user’s lock_wait_preference if not specified,
               see aeuconf(5) for more information.

       See also aegis(1) for options common to all aegis commands.

       All options may be abbreviated; the abbreviation is documented as the
       upper case letters, all lower case letters and underscores (_) are
       optional.  You must use consecutive sequences of optional letters.

       All options are case insensitive, you may type them in upper case or
       lower case or a combination of both, case is not important.

       For example: the arguments "-project, "-PROJ" and "-p" are all
       interpreted to mean the -Project option.  The argument "-prj" will not
       be understood, because consecutive optional characters were not
       supplied.

       Options and other command line arguments may be mixed arbitrarily on
       the command line, after the function selectors.

       The GNU long option names are understood.  Since all option names for
       aegis are long, this means ignoring the extra leading ’-’.  The
       "--option=value" convention is also understood.

RECOMMENDED ALIAS

       The recommended alias for this command is
       csh%    alias aeibu ’aegis -ibu \!* -v’
       sh$     aeibu(){aegis -ibu "$@" -v}

ERRORS

       It is an error if the change is not in the being_integrated state.
       It is an error if the change is not assigned to the current user and
       the current user is not a project administrator.

EXIT STATUS

       The aegis command will exit with a status of 1 on any error.  The aegis
       command will only exit with a status of 0 if there are no errors.

ENVIRONMENT VARIABLES

       See aegis(1) for a list of environment variables which may affect this
       command.  See aepconf(5) for the project configuration file’s project_
       specific field for how to set environment variables for all commands
       executed by Aegis.

SEE ALSO

       aeib(1) begin integration of a change

       aeuconf(5)
               user configuration file format

COPYRIGHT

       aegis version 4.24.3.D001
       Copyright (C) 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999,
       2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010 Peter
       Miller

       The aegis program comes with ABSOLUTELY NO WARRANTY; for details use
       the ’aegis -VERSion License’ command.  This is free software and you
       are welcome to redistribute it under certain conditions; for details
       use the ’aegis -VERSion License’ command.

AUTHOR

       Peter Miller   E-Mail:   millerp@canb.auug.org.au
       /\/\*             WWW:   http://www.canb.auug.org.au/~millerp/