NAME
aegis develop end undo - recall a change for further development
SYNOPSIS
aegis -Develop_End_Undo change-number [ option... ]
aegis -Develop_End_Undo -List [ option... ]
aegis -Develop_End_Undo -Help
DESCRIPTION
The aegis -Develop_End_Undo command is used to recall a change for
further development.
Successful execution of this command returns the change to the being
developed state. boxwid = 1 down S2: box "being" "developed" arrow "
develop" ljust " end" ljust S3: box "awaiting" "review" arrow " review"
ljust " begin" ljust S4: box "being" "reviewed" arrow " review" ljust "
pass" ljust S5: box "awaiting" "integration" T3: spline -> from S3.w
then left 0.50 then up 1 then to S2.w T4: spline -> from S4.w then
left 0.75 then up 2 then to S2.w T5: spline -> from S5.w then left
1.00 then up 3 then to S2.w "develop end " rjust "undo " rjust at
S2.w
The files are changed back to being owned by the current user, and
cease to be read-only.
Notification
On successful completion of the command, the develop_end_undo_notify_
command field of the project attributes file is run, if set. See
aepa(1) and aepattr(5) for more information.
OPTIONS
The following options are understood:
-Change number
This option may be used to specify a particular change within a
project. See aegis(1) for a complete description of this
option.
-Help
This option may be used to obtain more information about how to
use the aegis program.
-List
This option may be used to obtain a list of suitable subjects
for this command. The list may be more general than expected.
-Project name
This option may be used to select the project of interest.
When no -Project option is specified, the AEGIS_PROJECT
environment variable is consulted. If that does not exist, the
user’s $HOME/.aegisrc file is examined for a default project
field (see aeuconf(5) for more information). If that does not
exist, when the user is only working on changes within a single
project, the project name defaults to that project. Otherwise,
it is an error.
-REAson text
This option may be used to attach a comment to the change
history generated by this command. You will need to use quotes
to insulate the spaces from the shell.
-TERse
This option may be used to cause listings to produce the bare
minimum of information. It is usually useful for shell
scripts.
-Verbose
This option may be used to cause aegis to produce more output.
By default aegis only produces output on errors. When used
with the -List option this option causes column headings to be
added.
-Wait This option may be used to require Aegis commands to wait for
access locks, if they cannot be obtained immediately. Defaults
to the user’s lock_wait_preference if not specified, see
aeuconf(5) for more information.
-No_Wait
This option may be used to require Aegis commands to emit a
fatal error if access locks cannot be obtained immediately.
Defaults to the user’s lock_wait_preference if not specified,
see aeuconf(5) for more information.
See also aegis(1) for options common to all aegis commands.
All options may be abbreviated; the abbreviation is documented as the
upper case letters, all lower case letters and underscores (_) are
optional. You must use consecutive sequences of optional letters.
All options are case insensitive, you may type them in upper case or
lower case or a combination of both, case is not important.
For example: the arguments "-project, "-PROJ" and "-p" are all
interpreted to mean the -Project option. The argument "-prj" will not
be understood, because consecutive optional characters were not
supplied.
Options and other command line arguments may be mixed arbitrarily on
the command line, after the function selectors.
The GNU long option names are understood. Since all option names for
aegis are long, this means ignoring the extra leading ’-’. The
"--option=value" convention is also understood.
RECOMMENDED ALIAS
The recommended alias for this command is
csh% alias aedeu ’aegis -deu \!* -v’
sh$ aedeu(){aegis -deu "$@" -v}
ERRORS
It is an error if the change is not in one of the awaiting review or
being reviewed or awaiting integration states.
If is an error if the project has been configured to use the awaiting
review state, and the change is currently in the being reviewed state.
This is because the change currently belongs to the reviewer.
It is an error if the change was not developed by the current user.
EXIT STATUS
The aegis command will exit with a status of 1 on any error. The aegis
command will only exit with a status of 0 if there are no errors.
ENVIRONMENT VARIABLES
See aegis(1) for a list of environment variables which may affect this
command. See aepconf(5) for the project configuration file’s project_
specific field for how to set environment variables for all commands
executed by Aegis.
SEE ALSO
aede1 complete development of a change
aerpass1
pass review of a change
aerfail1
fail review of a change
aeuconf(5)
user configuration file format
COPYRIGHT
aegis version 4.24.3.D001
Copyright (C) 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999,
2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010 Peter
Miller
The aegis program comes with ABSOLUTELY NO WARRANTY; for details use
the ’aegis -VERSion License’ command. This is free software and you
are welcome to redistribute it under certain conditions; for details
use the ’aegis -VERSion License’ command.
AUTHOR
Peter Miller E-Mail: millerp@canb.auug.org.au
/\/\* WWW: http://www.canb.auug.org.au/~millerp/