Man Linux: Main Page and Category List

NAME

       tput - change terminal characteristics

SYNOPSIS

       tput [-T type] operand...

DESCRIPTION

       The  tput  utility  shall  display terminal-dependent information.  The
       manner in which this  information  is  retrieved  is  unspecified.  The
       information  displayed  shall clear the terminal screen, initialize the
       user’s terminal, or reset the user’s terminal, depending on the operand
       given.  The  exact  consequences  of  displaying  this  information are
       unspecified.

OPTIONS

       The tput utility shall  conform  to  the  Base  Definitions  volume  of
       IEEE Std 1003.1-2001, Section 12.2, Utility Syntax Guidelines.

       The following option shall be supported:

       -T  type
              Indicate  the  type  of terminal. If this option is not supplied
              and the TERM variable is unset or null, an  unspecified  default
              terminal  type  shall  be  used.  The setting of type shall take
              precedence over the value in TERM .

OPERANDS

       The  following  strings  shall  be  supported  as   operands   by   the
       implementation in the POSIX locale:

       clear  Display the clear-screen sequence.

       init   Display  the sequence that initializes the user’s terminal in an
              implementation-defined manner.

       reset  Display the sequence that  resets  the  user’s  terminal  in  an
              implementation-defined manner.

       If a terminal does not support any of the operations described by these
       operands, this shall not be considered an error condition.

STDIN

       Not used.

INPUT FILES

       None.

ENVIRONMENT VARIABLES

       The following environment variables shall affect the execution of tput:

       LANG   Provide  a  default value for the internationalization variables
              that are unset or null. (See  the  Base  Definitions  volume  of
              IEEE Std 1003.1-2001,    Section    8.2,    Internationalization
              Variables for the precedence of  internationalization  variables
              used to determine the values of locale categories.)

       LC_ALL If  set  to a non-empty string value, override the values of all
              the other internationalization variables.

       LC_CTYPE
              Determine the locale for  the  interpretation  of  sequences  of
              bytes  of  text  data as characters (for example, single-byte as
              opposed to multi-byte characters in arguments).

       LC_MESSAGES
              Determine the locale that should be used to  affect  the  format
              and contents of diagnostic messages written to standard error.

       NLSPATH
              Determine the location of message catalogs for the processing of
              LC_MESSAGES .

       TERM   Determine the terminal type. If this variable is unset or  null,
              and  if  the  -T option is not specified, an unspecified default
              terminal type shall be used.

ASYNCHRONOUS EVENTS

       Default.

STDOUT

       If standard output is a terminal device, it may be used for writing the
       appropriate  sequence  to  clear  the screen or reset or initialize the
       terminal. If standard  output  is  not  a  terminal  device,  undefined
       results occur.

STDERR

       The standard error shall be used only for diagnostic messages.

OUTPUT FILES

       None.

EXTENDED DESCRIPTION

       None.

EXIT STATUS

       The following exit values shall be returned:

        0     The requested string was written successfully.

        1     Unspecified.

        2     Usage error.

        3     No information is available about the specified terminal type.

        4     The specified operand is invalid.

       >4     An error occurred.

CONSEQUENCES OF ERRORS

       If  one  of  the  operands  is  not  available  for  the terminal, tput
       continues processing the remaining operands.

       The following sections are informative.

APPLICATION USAGE

       The difference between resetting and initializing a  terminal  is  left
       unspecified, as they vary greatly based on hardware types.  In general,
       resetting is a more severe action.

       Some terminals use control characters to perform the stated  functions,
       and  on  such  terminals  it  might make sense to use tput to store the
       initialization strings in a file or environment variable for later use.
       However,  because other terminals might rely on system calls to do this
       work, the standard output cannot be used in a portable manner, such  as
       the following non-portable constructs:

              ClearVar=tput cleartput reset | mailx -s "Wake Up" ddg

EXAMPLES

        1. Initialize  the  terminal  according to the type of terminal in the
           environmental variable TERM . This command can  be  included  in  a
           .profile file.

           tput init

        2. Reset a 450 terminal.

           tput -T 450 reset

RATIONALE

       The  list  of  operands  was  reduced  to  a  minimum for the following
       reasons:

        * The only features chosen were those that were likely to be  used  by
          human users interacting with a terminal.

        * Specifying  the  full terminfo set was not considered desirable, but
          the standard developers did not want to select among operands.

        * This volume of IEEE Std 1003.1-2001  does  not  attempt  to  provide
          applications  with  sophisticated terminal handling capabilities, as
          that falls outside of its assigned scope  and  intersects  with  the
          responsibilities of other standards bodies.

       The  difference  between  resetting and initializing a terminal is left
       unspecified as  this  varies  greatly  based  on  hardware  types.   In
       general, resetting is a more severe action.

       The  exit  status  of  1  is historically reserved for finding out if a
       Boolean operand is not set. Although the operands  were  reduced  to  a
       minimum,  the exit status of 1 should still be reserved for the Boolean
       operands, for those sites that wish to support them.

FUTURE DIRECTIONS

       None.

SEE ALSO

       stty , tabs

COPYRIGHT

       Portions of this text are reprinted and reproduced in  electronic  form
       from IEEE Std 1003.1, 2003 Edition, Standard for Information Technology
       -- Portable Operating System Interface (POSIX),  The  Open  Group  Base
       Specifications  Issue  6,  Copyright  (C) 2001-2003 by the Institute of
       Electrical and Electronics Engineers, Inc and The Open  Group.  In  the
       event of any discrepancy between this version and the original IEEE and
       The Open Group Standard, the original IEEE and The Open Group  Standard
       is  the  referee document. The original Standard can be obtained online
       at http://www.opengroup.org/unix/online.html .